Fosroc Lokfix E55S Vinyl Ester Chemical Anchor
A styrene-free vinyl-ester resin-based cartridge system designed for anchoring reinforcement and fixings across a wide range of substrates.
Description
Fosroc Lokfix E55S is a high-performance, styrene-free vinyl-ester anchoring system engineered for concrete, masonry, and diverse substrates. Ideal for structural reinforcement, threaded rod fixings, and post-installed rebar connections, it provides exceptional strength, chemical resistance, and durability.
Engineered to perform in both dry and wet conditions, Fosroc Lokfix E55S delivers excellent bonding even in extreme environments, including cracked concrete, submerged installations, and seismic zones. With fast curing and fire-rated properties, it is the professional choice for engineers and contractors across commercial, industrial, and infrastructure projects.
Key Features & Advantages
-
Styrene-free, low VOC – environmentally friendly.
-
High bond strength – suitable for heavy-duty anchoring.
-
Fast curing & early load capacity – enables rapid project completion.
-
Fire resistance – up to 120 minutes (Lokfix E55S).
-
Seismic rated – Category C1, tested and approved.
-
Usable with standard 300ml skeleton gun.
-
No expansive pressure – ideal for close-edge fixings.
-
Waterproof and corrosion-resistant.
-
Versatile application – dry, damp, or flooded conditions; horizontal, vertical, and overhead.
-
Reusable cartridge system – replace the static mixer after use.
-
Compliant with ETA and EAD international standards.
Typical Applications
Fosroc Lokfix E55S is widely used for:
-
Post-installed reinforcement bars (rebar)
-
Anchoring threaded rods, bolts, and internal sleeves
-
Bonding and crack sealing on concrete surfaces
-
Submerged installations in marine or water-retaining structures
-
Structural anchoring in bridges, tunnels, and high-rise buildings
-
Solid and hollow masonry, porous concrete, and lightweight blocks
Perfect for both new construction and repair/retrofit projects, where structural integrity and chemical durability are essential.
Technical Data
| Property | Test Method / Unit | Result |
|---|---|---|
| Compressive Strength | EN196 | 100 MPa |
| Flexural Strength | EN196 | 15 MPa |
| Elastic Modulus (E) | EN196 | 14,000 MPa |
| Shore D Hardness | – | 90 |
| Density | – | 1.77 kg/L |
| Permanent Service Temp. | – | –40°C to +72°C |
| Service Temperature Range | – | –40°C to +120°C |
| Electrical Resistance | IEC93 | 3.6 × 10⁹ Ω·m |
| Thermal Conductivity | IEC 600093 | 0.65 W/m·K |
| VOC Level | LEED Compliant | A+ (Low Emission) |
| Fire Resistance | ETA | 120 min (E55S only) |
| Seismic Rating | EAD 330499 | Category C1 |
Curing Time (at 20°C):
-
Gel Time: 6 minutes
-
Dry Conditions: 45 minutes
-
Damp/Wet Conditions: approximately double
-
Optimal Cartridge Temperature: +15°C to +30°C
Low-temperature variant: Fosroc Lokfix E55L (-20°C to +15°C, without seismic/fire rating).
Design & Installation Guidance
Drilling & Hole Preparation
-
Drill hole to required diameter and depth with a percussion drill.
-
Clean thoroughly using wire brush and compressed air (4× blow, 4× brush, 4× blow).
-
Ensure the hole is dry and dust-free.
Application Procedure
-
Attach static mixer nozzle to the cartridge.
-
Load into a standard 300ml skeleton gun.
-
Dispense until resin color is uniform (discard initial material).
-
Fill hole from the back (approx. ¾ full) to avoid air gaps.
-
Insert fixing rod slowly with twisting motion.
-
Allow full curing before loading.
Note: Do not over-torque bolts; follow recommended torque limits. For reuse, replace static mixer and recap cartridge.
Design Standards & Approvals
-
ETA-18/0587, ETA-18/0586, ETA-18/0585 – Certified performance & safety
-
EAD 330499-00-0601 – Post-installed rebar, cracked/uncracked concrete
-
EAD 330076-00-0604 – Anchoring in masonry
-
ETAG 001 TR 023 & TR 029 – Superseded, fully compliant
-
LEED & low VOC (A+) – Environmentally friendly
Packaging & Accessories
-
Supplied in 300ml cartridges, 12 per box
-
Each cartridge includes 1 static mixer nozzle
-
Available accessories: extension nozzles, hollow block sleeves, piston plugs, steel cleaning brushes, dust blower pumps, hand applicator guns
Yield Formula:
Consumption (ml)=(πrhole2−πrbolt2)×Hole Length (cm)\text{Consumption (ml)} = (\pi r_\text{hole}^2 – \pi r_\text{bolt}^2) \times \text{Hole Length (cm)}
Include allowances for extrusion, waste, and over-drilling.
Storage & Shelf Life
-
Shelf Life: 12 months (unopened)
-
Storage: +5°C to +25°C, dry warehouse
-
Protect from direct sunlight & frost
Health & Safety
-
Read and follow the SDS
-
Avoid contact with skin and eyes
-
Use gloves and eye protection
-
Ensure adequate ventilation
-
Clean uncured material with Nitoflor Sol








Reviews